Deck-man |
Formwork
Applicable |
Deck plate |
Use |
For heavy equipment |
Type |
Press-in type |
|
|
|
|
Features |
|
●Easy installation by inserting into the drilled hole and driven by a hammer.
●Color can be checked from the top and bottom of the deck plate.
●Suitable for hanging heavy items like sanitary and air conditioning systems
●Insured with product liability insurance
●Cross type is also available |
|
※Use[Spring Hanger] spring type for thin plate
(Keystone plate) to prevent tipping of the insert. |
|
|
|
|
Part No.List-Code No.M10067 Deck-man |
*Pullout test values are values when the insert breaks |
Unit:mm |
|
Part No. |
Thread size |
Effective
Embedded
Depth(mm) |
Drill
Diameter
(mm) |
Embedded in Concrete, Pullout Test Result |
Quantity/
Case
(pcs) |
Color |
Effective
Thread
Length S |
Diameter
of Head
D |
Diameter
of Core
d |
Height
H |
Thickness
of Head
h |
Ave.
Pullout Force(kN) |
Concrete
Compressive
Strength(N/mm2) |
DM-3040 |
W3/8 |
42.5 |
15.0 |
20.8 |
23.6 |
300 |
|
13 |
22 |
12 |
45 |
2.5 |
DM-3050 |
W3/8 |
52.5 |
15.0 |
26.8 |
23.6 |
200 |
|
13 |
22 |
12 |
55 |
2.5 |
DM-4060 |
W1/2 |
64 |
21.0 |
37.1 |
17.6 |
100 |
|
25 |
28 |
17 |
68 |
4 |
DM-5075 |
W5/8 |
80 |
25.5 |
61.2 |
24.2 |
50 |
|
30 |
37 |
22 |
85 |
5 |
DM-M1260 |
M12 |
64 |
21.0 |
37.1 |
17.6 |
100 |
|
25 |
28 |
17 |
68 |
4 |
DM-M1675 |
M16 |
80 |
25.5 |
61.2 |
24.2 |
50 |
|
30 |
37 |
22 |
85 |
5 |
|
|
Items in square brackets are the set available upon order. |
|
Placement Procedure |
|
1.Cut a hole at the marked position precisely using a drill
or hole saw of the specified diameter(boring tools)
2.Place the insert into the hole.
3.Tap the head of the insert with a hammer and lock the
insert.
4.Screw in a bolt to the full depth to prevent loosening. |
|
|
|
|
|