InsulationVarious Formwork
Applicable
:For plywood and insulation
Use :For light equipment
Type :For insulation and self-pullout nails

Color
Click the appointed color.
Features

●Self-standing with three nails
●Easy to place with only one hand
●After the formwork is removed,the color is visible from the bottom of the slab.
●Suitable for hanging lightweight items like electrical and disaster prevention systems
●A Slidart Punch comes with the inserts
when purchased by the case.
●When the formwork is removed,nails are also removed with the plywood and the ceiling slab is clean.
●If a nail remains embedded in the slab,pull out using pliers etc.
 
 
 
Part No.List-Code No. M16327 Insulation Various ※Pullout test values are values when the insert breaks                 Unit:mm
Part No. Thread
size
Effective
Embedded
Depth(mm)
Insulation
Thickness
(mm)
Embedded in Concrete,Pullout Test Result Quantity/
Case(pcs)
Color Effetive Thread Length S Diameter of Head
Diameter of Core
Height
Thickness of Head
Insulation Layer
Ave.
Pullout Force(kN)
Concrete Compressive Strength(N/mm2)
DV-3025 W3/8 30 25・30 14.6 25.0 400 RD・BL・YL・WT・GR 13 28 12 32.5 2.5 24
DV-3035 W3/8 30 35・38・40・45・50 14.6 25.0 200 RD・BL・YL・WT・GR 13 28 12 32.5 2.5 34
 
Placement Procedure
1.Open a hole into an insulation using a Slidart punch (twist-in vertically).
2.Press the insert into the opening of the insulation.
3.Drive the insert with a hammer vertically and anchor firmly.
4.Screw in a bolt to the full depth to prevent loosening

Precautions in Placement
・The insert may be lifted due to vibration when another insert is driven.Before concrete is placed,check that the inserts are completely driven in without lifting.
・Due to various factors,the nails may remain embedded in the ceiling slab, embedded nails must be pulled out using pliers etc.
・Drive the insert carefully so that the base of the insert will not penetrate into the insulation.